Troubleshooting ​

The setup code is lost ​

Start pvmon again. If no account exists, pvmon writes a new code to the log.

A password is lost ​

  1. Stop pvmon.

  2. Set a new password:

    bash
    printf '%s\n' "$PASSWORD" | pvmon user reset-password admin

The web interface cannot change a setting ​

config.yaml or an environment variable defines the setting. Change it there.

pvmon does not start ​

  1. Read the log. pvmon shows each configuration error with the path of the key, for example meters.grid.device: unknown device "meterr".
  2. Correct the errors.
  3. Run pvmon config validate.

A Modbus device reports "illegal data address" ​

Set read: direct for this device.

A Modbus device is offline frequently ​

Many gateways and RS485 buses can answer only one request at a time.

  • Give all devices of one bus the same connection.
  • Increase the poll interval.
  • Make sure that no other program reads the device.

Import and export are higher than on the utility meter ​

Refer to Grid netting.

A day shows n/m days or the mark ≈ ​

Refer to Energy and data quality.

The browser cannot install the app ​

The browser must use HTTPS or localhost.