Example setups
pvmon has tests for these setups. You can start each setup with simulated devices:
bash
pvmon simulate --setup R4| ID | Devices | Result |
|---|---|---|
| R1 | One hybrid inverter with a battery | The inverter supplies PV, battery and grid |
| R2 | A hybrid inverter and a second PV inverter | Only one device supplies grid values |
| R3 | A separate grid meter | The grid values come from this meter |
| R4 | Two wallboxes and a heat pump | The flow shows one node for each category |
| R5 | Two batteries on two inverters | The state of charge uses the capacities as weights |
| R6 | A micro inverter without an energy counter | pvmon calculates energy from power (≈) |
| R7 | Separate PV strings | Each string is a pv meter below the PV total |
Separate grid meter
The inverter also supplies grid values. Use them only for diagnosis:
yaml
meters:
inv-grid: { device: wr1, source: grid, role: inverter }
grid: { device: meter, source: total, critical: true }With critical: true, GET /health gives an error if this meter is offline longer than status.offline_after.
Wallbox and heat pump
yaml
devices:
goe: { address: "http://10.0.0.40", profile: goe/charger-v2, interval: 10s }
hp-meter: { connection: lan-solis, unit: 2, profile: eastron/sdm630 }
meters:
wb-garage: { device: goe, source: charger, label: Garage }
heatpump: { device: hp-meter, source: total, role: consumer, category: heatpump, parent: site }PV strings
yaml
meters:
pv: { device: wr1, source: pv, kwp: 10, label: Roof }
pv-mppt1: { device: wr1, source: pv1, parent: pv, label: South }
pv-mppt2: { device: wr1, source: pv2, parent: pv, label: West }