Grid netting
In a three-phase system, one phase can import and a different phase can export at the same time. Most utility meters first add the phases. Some devices count each phase separately. Their import and export values are then too high.
Setting
Set netting on the device of the grid meter:
| Value | Function | Use it if |
|---|---|---|
meter | pvmon uses the import and export counters of the device | the device adds the phases |
app | pvmon adds import and export at each poll and books the result | the device counts each phase separately |
devices:
meter: { address: "tcp://10.0.0.50:502", profile: eastron/sdm630, netting: app }Each profile that can supply a grid meter has a default value. Your configuration has priority.
| Profile | Default |
|---|---|
shelly/pro-3em | meter |
shelly/3em | meter (not verified) |
eastron/sdm630 | app |
solis/s6-hybrid | app |
In a single-phase system, app causes no error.
Method of app
If the counters have steps of 1 Wh or less, pvmon uses the difference between the import and export counters. If the steps are larger, pvmon calculates the energy from the total power.
Poll the grid meter every 1 to 2 seconds on a separate connection. If the direction of the total power changes between two polls, import and export are too low. With fine counters, the difference between import and export stays correct.
How to select the value
Compare the counters of the device:
| Observation | Device | Value |
|---|---|---|
| The sum of the phase imports is equal to the total import. This is also true for export | counts each phase separately | app |
| The two totals are lower than the phase sums by the same quantity | adds the phases | meter |
pvmon does not do this comparison.