Skip to content

Grid netting ​

In a three-phase system, one phase can import and a different phase can export at the same time. Most utility meters first add the phases. Some devices count each phase separately. Their import and export values are then too high.

Setting ​

Set netting on the device of the grid meter:

ValueFunctionUse it if
meterpvmon uses the import and export counters of the devicethe device adds the phases
apppvmon adds import and export at each poll and books the resultthe device counts each phase separately
yaml
devices:
  meter: { address: "tcp://10.0.0.50:502", profile: eastron/sdm630, netting: app }

Each profile that can supply a grid meter has a default value. Your configuration has priority.

ProfileDefault
shelly/pro-3emmeter
shelly/3emmeter (not verified)
eastron/sdm630app
solis/s6-hybridapp

In a single-phase system, app causes no error.

Method of app ​

If the counters have steps of 1 Wh or less, pvmon uses the difference between the import and export counters. If the steps are larger, pvmon calculates the energy from the total power.

Poll the grid meter every 1 to 2 seconds on a separate connection. If the direction of the total power changes between two polls, import and export are too low. With fine counters, the difference between import and export stays correct.

How to select the value ​

Compare the counters of the device:

ObservationDeviceValue
The sum of the phase imports is equal to the total import. This is also true for exportcounts each phase separatelyapp
The two totals are lower than the phase sums by the same quantityadds the phasesmeter

pvmon does not do this comparison.

Version 0.4.0-66c93c2. MIT license.